DeviceNet 快速连接模块
DA4
|
|
DeviceNet Module with (2) Mini Connectors for DeviceNet and Aux. Power Interface. Supports Double Solenoid Valve with TSI on Master. Arc Prevention applied to Aux1, Aux2, and CAN V+ power. Lock, Unlock, and RTL sensing with LED cables on the Master. Tool-ID from the Tool module also supported. |
|
|
DB10
|
|
Quick Connect Capable DeviceNet Module with (2) Mini Conn for DeviceNet and Aux. Power Interface, TSI on Tool, Arc Prevention applied to Aux1, Aux2, and CAN V+ power. Lock/Unlock/RTL Sensing, LED Cables on Master. Tool-ID from Tool module also supported. |
|
|
Control modules - 24VDC Pass-through signals - 5 Amp/24VDC |
|
DB10Z1-M,DB10-T,DB13-T
|
|
Quick Connect Capable DeviceNet Module with (2) Mini Conn for DeviceNet and Aux. Power Interface, TSI on Tool, Arc Prevention applied to Aux1, Aux2, and CAN V+ power. Lock/Unlock/RTL Sensing, LED Cables on Master. Tool-ID from Tool module also supported. |
|
|
Control modules: 24VDC Pass-through signals: 5 Amp/24VDC |
|
DB12-M,DB10-T
|
|
Quick Connect Capable DeviceNet Module with Arc Prevention, no TSI Bypass, Block Latch without Tool |
|
|
Control modules - 24VDC Pass-through signals - 3 Amp/30VDC |
|
DB12-M,DB13-T
|
|
Quick Connect Capable DeviceNet Module with (2) Mini Connectors for DeviceNet and Aux. Power Interface, TSI on Tool w/ No RTL Bypass and Latch Disable Function, Arc Prevention applied to Aux1, Aux2, and CAN V+ power. Lock, Unlock, and RTL sensing with LED cables on the Master (RTL Sensors in Series). Tool-ID from the Tool module also supported |
|
|
Control modules - 24VDC Pass-through signals - 3 Amp/30VDC |
|
DB15-M,DB10-T
|
|
Quick Connect Capable DeviceNet Module with (2) Mini Connectors for DeviceNet and Aux. Power Interface, TSI on Tool, No RTL Bypass, Arc Prevention applied to Aux1, Aux2, and CAN V+ power. Lock, Unlock, and RTL sensing with LED cables on the Master (RTL Sensors in Series). Includes 3-Pin M8 Connector for Air Supply Pressure Monitoring. Tool-ID from the Tool module also supported. |
|
|
Control modules - 24VDC Pass-through signals - 3 Amp/30VDC |
|
DB2
|
|
DeviceNet Module, Supporting an Integrated Valve with Tool Stand Interlock (TSI) on Tool |
|
|
|
|
DeviceNet模块
DU3
|
|
DeviceNet Module with (2) Mini Connectors for DeviceNet and Aux. Power Interface. Supports Double Solenoid Valve Adapter. Supports Air Supply monitoring via Pressure Switch input. Arc Prevention applied to Aux1, Aux2, and CAN V+ power. Supports NPN Lock, Unlock, Thermal 1, and RTL sensors (RTL sensors in series). Tool-ID from the Tool module also supported. |
|
|
|
|
DeviceNet通过模块
DR2
|
|
DeviceNet and Auxiliary Power Pass-through Module |
|
|
DeviceNet - 3 Amp max. Auxiliary Power - 9 Amp max. |
|
G5
|
|
19-pin, 3 Amp/250VAC Electrical Module with 5-pin DeviceNet Connector and 5-position Swivel |
|
|
KD5
|
|
Electrical Module with (1) M12 5-Pin Male Connector |
|
|
RD5
|
|
4 Amp/250VAC electrical module with 5-pin M12 connector |
|
|
TD
|
|
10-pin, 5 Amp/24V, pass-through DeviceNet and Aux power module |
|
|
TDEA
|
|
DeviceNet Pass-Through Module with M12 Connectors Redundant Signals |
|
|
DeviceNet - 4 Amp/250V Aux Power - 5 Amp/600V |
|
|
|
Ethernet/EtherNetIP/EtherCAT/PROFINET 100Mb通讯模块
DT2
|
|
EtherNet/IP Pass-through Module w/Aux. Power Pass-through for Utility Coupler Applications. |
|
|
Power Pass-through - 8 Amp/12-30VDC Signal Pass-through - 3 Amp/250V maximum |
|
GBX
|
|
10 Gigabit Ethernet Pass-Through Module, M12 X-coded |
|
|
Power: 0.6 A / 60 V Signal: 10 Gbps / CAT6A |
|
KE7
|
|
K-style Ethernet (M12, 4-Pin D-Coded Receptacle) and Power (M8, 3-Pin Receptacle) Electrical Module |
|
|
KE8
|
|
K Style Ethernet (M12 4-Pin D-Coded Receptacle) and Power (M8 4-Pin Male Receptacle) Electrical Module |
|
|
ME10
|
|
ME10 Electrical Module, M12 D-Code, M12 L-Code |
|
|
Signal (.6Amp/60V max.) Power (4Amp/63VDC max.) |
|
ME10A
|
|
ME10A Electrical Module, M8 D-Code, M8 A-Code |
|
|
Signal (.6Amp/60VDC max.) Power (3Amp/60VDC max.) |
|
RE10
|
|
10/100 CAT5e Ethernet Pass-through Module |
|
|
RE5
|
|
Ethernet Pass-through Module with 4-pins and Shield |
|
|
RE8
|
|
Ethernet Pass-through Module with 8-pins and Shield |
|
|
S5EPD
|
|
Ethernet Module with Viton Seals, Potted |
|
|
TE
|
|
Ethernet Pass-through Module with connectors for Ethernet and Aux Power |
|
|
Ethernet Circuit - 2 Amp/60VAC max. Auxiliary Power Circuit - 5 Amp/600VAC max. |
|
TES
|
|
Ethernet Pass-through Module with connectors for Ethernet and Aux Power, Axial orientation. Straight connectors on Tool side. |
|
|
Aux Power - 4 Amps Signal - 2 Amps |
|
TME
|
|
Pass-through Module with Connectors for Ethernet, Aux Power, and Servo Power |
|
|
Ethernet Circuit - 2 Amp/150V Aux Power Circuit - 6 Amp/250V Servo Power Circuit - 6 Amp/250V |
|
TP
|
|
PROFINET Pass-through Module with connectors for PROFINET and Aux Power, 5-Pin Aux Power |
|
|
PROFINET Circuit - 2 Amp/60VAC max. Auxiliary Power Circuit - 5 Amp/600VAC max. |
|
VL1
|
|
EtherCAT Control Module Assembly |
|
|
EtherCAT - 3 Amp/30VDC max. US1 Power - 220mA @ 24VDC US2 Power - 250mA @ 24VDC |
|
|
|
EtherNet/IP模块
CYE1
|
|
Ethernet IP Module with intergrated 4-Pin D-Coded M12 connector for Ethernet communication, 4-Pin Minfast Connector for US1 and US2 power, TSI on the Tool, Arc Prevention applied to US1 and US2, and integrated web server for tool changer communication configuration and Ethernet switch management. Lock, Unlock, RTL sensing and IP address setting option on the Master. Tool-ID from the Tool module also supported. |
|
|
Input Power: 4A, 21.6-30V Output Power 7A, 20-30V |
|
DKF
|
|
EtherNet/IP Module with integrated Ethernet switch, supports DHCP functionality and EtherNet/IP Quick Connect |
|
|
Control Signals - 24VDC Pass-through Signals - 5 Amp/250V |
|
DKG-M,DKF-T,DKQ-T
|
|
EtherNet/IP Module w/integrated switch supporting DHCP, Quick Connect, Input and Switched Auxillary Power pass-thru, TSI on Tool. M12 D-coded Connector for Ethernet communication, Mini 4-pin Connector for Input power/Switched Aux Power. Lock/Unlock/RTL. |
|
|
Control Signals - 24VDC Pass-through Signals - 5 Amp/250V |
|
DKK-M,DKF-T
|
|
EtherNet/IP Module with integrated Ethernet switch supporting DHCP functionality and EtherNet/IP Quick Connect, Input and Switched Auxillary Power pass-through, Non-RTL Bypassed TSI on Tool. M12 D-coded Female Connector for Ethernet communication, one Mini 4-Pin Male Connector for Input power and for Switched Auxillary Power. Lock, Unlock and RTL sensing with LED cables on the Master and Tool-ID from the Tool module are also supported. Arc Prevention Circuit applied to AUX Switched and Input power. |
|
|
Control Signals - 24VDC Pass-through Signals - 5 Amp/250V |
|
DKL
|
|
EtherNet/IP Module with Integrated Ethernet Switch, 4-Pin M12 D-Coded connector for Ethernet communication, 4-Pin MiniFast Connector for Input and Output Power, TSI on the Tool, Arc Prevention applied to Input and Output power. Lock, Unlock, and RTL sensing with LED cables on the Master. Tool-ID from the Tool Module also supported. Safety circuit meets ISO13849 PLd |
|
|
Power - 180 mA @ 24 VDC Valve Power (switched Auxiliary Power) - 250 mA @ 24 VDC (Solenoid Valve) (only when locking or unlocking Tool Changer) Pass-through Power - 5 Amp/20-29 VDC |
|
DKP
|
|
EtherNet/IP Module with integrated Ethernet switch, supports DHCP functionality and EtherNet/IP Quick Connect, Input and Aux. Power pass-through, TSI on Tool. M12 D-coded Connector for Ethernet communication, Mini 4-Pin Connector for Output, Input and Logic Power. Lock, Unlock and RTL sensing with LED cables on the Master and Tool-ID from the Tool module are also supported. Supports RTL Bypass with both sensors in series. Arc Prevention Circuit applied to Aux. Switched and Aux. Unswitched. |
|
|
Pass-through Power - 5 Amp/24VDC max. |
|
DKR
|
|
EtherNet/IP Module with integrated Ethernet switch, 4-Pin M12 D-Coded connector for Ethernet communication, Mini 4-Pin Male Connector for Switched and Unswitched Auxiliary Power, 5-Pin M12 to support TSI on the Tool, 4-Pin M12 Connector to support Thermal 1 Input, 0-99999 Tool-ID through to the Master moduleTSI on the Tool, Arc Prevention applied to Switched and Unswitched Aux power. Lock, Unlock, and RTL sensing with LED cables on the Master. Tool-ID from the Tool module also supported. Safety circuit meets ISO13849 PLd |
|
|
DKRZ1
|
|
EtherNet/IP Module with integrated Ethernet switch, 4-Pin M12 D-Coded connector for Ethernet communication, Mini 4-Pin Male Connector for Switched and Unswitched Auxiliary Power, 5-Pin M12 to support TSI on the Tool, 4-Pin M12 Connector to support Thermal 1 Input, 0-99999 Tool-ID through to the Master module. Matching Ethernet ports on Master and Tool. TSI on the Tool, Arc Prevention applied to Switched and Unswitched Aux power. Lock, Unlock, and RTL sensing with LED cables on the Master. Tool-ID from the Tool module also supported. Safety circuit meets ISO13849 PLd. |
|
|
DKS
|
|
EtherNet/IP Module with integrated Ethernet switch supporting DHCP functionality and EtherNet/IP Quick Connect, Input and Switched Auxillary Power pass-through, Non-RTL Bypassed TSI on Tool. M12 D-coded Female Connector for Ethernet communication, one Mini 5-Pin Male Connector for Input power and for Switched Auxillary Power. Lock, Unlock and RTL sensing with LED cables. Tool side has 0-9 Tool-ID switches. |
|
|
Pass-through Signals - 5 Amp/24VDC max. Power - 180 mA @ 24VDC, Master only (Unlocked sensor "ON", Locked) Valve Power (switched Auxiliary Power) - 250 mA @ 24VDC (Solenoid Valve) (only when locking/unlocking Tool Changer) Tool-ID switch - 0.1 Amp/30VDC |
|
|
|
Insta工具模块
There are currently no modules in this category.
|
|
|
PROFIBUS模块
VG3
|
|
Discrete PROFIBUS Pass-through Module |
|
|
|
|
PROFINET模块
DL10
|
|
PROFINET Module with integrated Ethernet switch, D-Coded 4-Pin M12 connector for PROFINET communication, 5-Pin Mini Connector for US1 and US2 power, TSI on the Tool, Arc Prevention applied to US1 and US2 power. Lock, Unlock, and RTL sensing with LED cables on the Master. Tool-ID from the Tool module also supported. |
|
|
Safe Power - 24 VDC I/O+ and 24VDC 10 Amp/ 12-30VDC |
|
DL12
|
|
PROFINET Module with integrated Ethernet switch. D-Coded 4-Pin M12 connector for PROFINET communication, 5-pole Mini Connector for Switched and Unswitched Auxiliary power. Arc Prevention applied to Switched and Unswitched Auxiliary power. Lock, Unlock, and RTL sensing with LED cables on the Master. Tool-ID from the Tool module also supported. Safety circuit meets ISO13849 PLd. |
|
|
Power Pass Through - 10 Amp Signal - 3 Amp/30VDC max. |
|
DL16
|
|
PROFINET Module with integrated Ethernet switch, D-Coded 4-Pin M12 connector for PROFINET communication, 5-Pin Mini Connector for US1 and US2 power, TSI on the Tool, Arc Prevention applied to US1 and US2 power. Lock, Unlock, and RTL sensing with LED cables on the Master. Tool-ID from the Tool module also supported. |
|
|
Auxiliary Power: 9 Amp / 20-29 VDC
Profinet: 1 Amp / 30VDC max
Note: Arc prevention is applied to US1 and US2 power. |
|
DL4
|
|
PROFINET Module with RJ45 Push-Pull Ethernet and 5-Pin Push-Pull Power Connectors, Arc Prevention. 0-99999 Tool-ID. TSI on Tool side. |
|
|
US1 and US2 Power - 10 Amp/12-30VDC |
|
DL8
|
|
PROFINET Module with integrated Ethernet switch, RJ45 Push-Pull connector for Ethernet communication, 5-Pin Push-Pull Connector for US1 and US2 power, 10-Pin Push-Pull Hybrid Connection, TSI on the Tool, Arc Prevention applied to US1 and US2 power. Lock, Unlock, and RTL sensing with LED cables on the Master. 5-digit Tool-ID from the Tool module also supported. Safety circuit meets ISO13849 PLd. |
|
|
Power Pass-through - 10 Amp Signal - 3 Amp/30 VDC max. |
|
DT4
|
|
PROFINET Pass-Through Module w/ Aux. Power Pass-Through for Utility Coupler Applications. M12 D-coded Female Connector for PROFINET communication, Mini 5-Pin Male Connector for Switched and Un-Switched Aux. Power circuits. Two (2) M12 4-Pin Connectors for Connection Verification signal and Arc Prevention Control. Arc Prevention Circuit applied to Aux. Switched, Aux. Unswitched. |
|
|
Power - 8 Amp/12-30VDC Signal - 3 Amp/250V max. |
|
|
|
信号控制模块
CV14 Family
|
|
Compact Discrete Control/Valve Module with Locked/Unlocked Sensor Cables, Tool Stand Interlock (TSI), 0-F Tool ID. |
|
|
Input - 24V (+20%/-10%) / 4A Spare Pass-Through Signals - <50V / 3A Tool ID - 30V / 100mA |
|
|
|
双冗余DeviceNet 模块
There are currently no modules in this category.
|
|
|
离散的模块
SA10
|
|
Discrete, 24-Pin MS3102 Connector, Supports NPN Lock, Unlock, and RTL Sensors (RTL in Series), No Integrated Valve Control, No Tool-ID or TSI on Tool. |
|
|
Control signals - 24VDC Pass-through signals - 5 Amp/250V |
|
SA12-M,SA2-T
|
|
Discrete Module, 19-Pin MS3102 Connector, Supports PNP Lock, Unlock, and RTL Sensors, No Integrated Valve Control |
|
|
Control signals - 24VDC Pass-through signals - 5 Amp/250V |
|
SA2,SA3
|
|
Discrete Module, 26-pin Amphenol, 19-pin Block, Supports Lock/Unlock/R1/R2 Sensors, Tool ID on Tool side. (Not intended for use with an integrated valve.) |
|
|
Control signals - 24VDC Pass-through signals - 5 Amp/250V |
|
SC29
|
|
Harting Module, Supports Servo Power and Redundant Encoder and Ethernet Signals, Supports L/U/R1/R2 Sensors and Integrated Valve, Supports TSI on the Tool with no RTL bypass. |
|
|
Signal - 5 Amp/250V Motor Power - 13 Amp/400V Ethernet Signals - 2 Amp/60V Tool Changer (TSI) - 4 Amp/24V Tool Changer (Tool-ID) - 100 mA/50V Tool Changer (Valve Control) - 19-29V Sensors (Lock, Unlock, RTL) - 10-30 VDC oper voltage, 150mA Oper Current |
|
SC30
|
|
Discrete Module, 25-Pin HAN-D Harting Connector, 5-Pin Minifast Aux Power and 4-Pin M12 D-Coded Connector with Redundant PROFINET Pass-Through, Supports L/U/R1/R2 Sensors and Integrated Valve, 0-9 Rotary Switch Tool-ID, Supports TSI with no RTL bypass on the Tool |
|
|
Aux Power - 5 Amp/250V Signal - 5 Amp/250V PROFINET Signals - 4 Amp/250V Tool Changer (TSI) - 4 Amp/24V Tool Changer (Tool-ID) - 100 mA/50V Tool Changer (Valve Control - 19-29V Sensors (L,U,RTL) - 10-30VDC Operational Voltage, 150 mA Operational Current |
|
SC32
|
|
Harting Module with Redundant Wiring, Supports Servo Power and Encoder Signals, PROFIBUS/DeviceNet Pass-through, Supports L/U/R1/R2 Sensors and Integrated Valve, Supports TSI on the Tool and Master. |
|
|
Power - 15 Amp/500V (Harting Block c) Signal - 3 Amp/24V (Harting Block b) PROFIBUS/DeviceNet Pass-through - 3 Amp/24V (Harting Block a) TSI - 1 Amp/30V Tool-ID - 100mA/24V |
|
SC7
|
|
Harting Module, Supports Servo Power and Encoder Signals, PROFIBUS/DeviceNet Pass Thru, Supports L/U/R1/R2 Sensors and Integrated Valve, 0-9 Tool-ID, Supports TSI on the Tool |
|
|
Power - 7 @ 15 Amp/500V Signal - 14 @ 3 Amp/24V Tool Changer - 6 @ 3 Amp/24V Fieldbus - 12 @ 3 Amp/24V |
|
SC8
|
|
Harting Module that supports Servo Power and Encoder Signals, PROFIBUS Pass Thru, Supports L/U/R1/R2 Sensors and Integrated Valve, Supports TSI on Tool |
|
|
Power - 7 @ 13 Amp/500V Signal - 17 @ 3 Amp/24V Tool Changer (TSI and Tool-ID) - 6 @ 3 Amp/24V Fieldbus - 2 @ 3 Amp/24V |
|
SD2
|
|
Discrete Module with M23, 17-pin connector, Supporting PROFIBUS I/O Block and TSI on Tool |
|
|
Control Signals - 24VDC Pass-through Signals - 5 Amp/250V |
|
VA2
|
|
Discrete Module, 26-pin Amphenol, 19-pin Block, Supports L/U/R1/R2 sensors and Integrated Valve, works with SA Tool-side modules, TSI on Master |
|
|
Control Signals - 24VDC Pass-through Signals - 5 Amp/250V |
|
VA6 Family
|
|
Discrete Module, 26-Pin Amphenol, 19-Pin Block, Supports L/U/R1/R2 Sensors with Integrated Valve Pass-through
VA6-M Supports TSI on the Master Side and Works with SA Series Tools |
|
|
Control Signals - 24VDC Pass-through Signals - 5 Amp/250V |
|
VA7 Family
|
|
Discrete Module, 26-Pin Turck M27 Connector, 19-Pin Block, Supports L/U/R1/R2 Sensors with Integrated Valve Pass-through.
VA7-M Supports TSI on the Master Side and Works with SA Series Tools |
|
|
Control Signals - 24VDC Pass-through Signals - 5 Amp/250V |
|
VB11
|
|
Discrete Module, Supports L/U/R1/R2 PNP Sensors and Integrated Valve, 35-Pin DDK (MS Style) Connector, TSI on Tool, 0-9 Tool-ID, 22 Pass-Through |
|
|
Control signals - 24VDC Pass-through signals - 5 Amp/250V |
|
VB12-M,VB13-M,VB12-T
|
|
Discrete Signal Module with 36-Pin PT Bayonet Connector, TSI on Master, Supports L/U/R1/R2 PNP Sensors and Integrated Valve (R1 and R2 in Series). (VB13-M connector mounted on Right Angle Spacer Block.) |
|
|
Control Signals - 24VDC Pass-through Signals - 5 Amp/250V |
|
VB18
|
|
Discrete Signal Module w/35-pin Amphenol on Master, 24-pin Amphenol on Tool. 5-pin Aux Power, 4-pin PROFINET pass-through, 17-pin and 26-pin blocks. |
|
|
5 Amp/250V max Tool-ID Switch - 0.1 Amp/30V |
|
VB2
|
|
Discrete Module, 26-pin Amphenol, 19-pin Block, Supports L/U/R1/R2 Sensors and Integrated Valve,TSI on Tool |
|
|
Control Signals - 24VDC Pass-through Signals - 5 Amp/250V |
|
VB5
|
|
Discrete Module, 19-pin Amphenol, 19-pin Block, Tool Side Tool Stand Interlock, 10 Pass-Throughs, NPN (sinking) Locked, Unlocked, and RTL sensors |
|
|
Control Signals - 24VDC Pass-through Signals - 5 Amp/250V |
|
VB7 Family
|
|
Discrete Module, 26 Pin Amphenol, 19-pin Block, Supports L/U/R1/R2 Sensors w/ Integrated Valve Pass-Through (uses single or double solenoid valve), TSI on Tool and Tool-ID (Mates with VB Series Tools) |
|
|
Control Signals - 24VDC Pass-through Signals - 5 Amp/250V |
|
VB7Z1 Family
|
|
Discrete Signal Module with 26-Pin Amphenol, 19-pin Block, Supports L/U/R1/R2 Sensors with Integrated Valve Pass-yhrough (Uses Double Solenoid Valve) **Supports Tool Stand Interlock on Tool Side. |
|
|
Signal Pass-through - 5 Amp/250V max. |
|
VB8
|
|
Discrete Module, Supports L/U/R1/R2 NPN Sensors and Integrated Valve, 37-Pin DDK Connector, TSI on Tool, 0-7 Tool-ID |
|
|
Control Signals - 24VDC Pass-through Signals - 5 Amp/250V |
|
VD2
|
|
Discrete Module, 26-pin Amphenol, Remote I/O Connection, 19-pin Block, Supports L/U/R1/R2 Sensors and Integrated Valve, TSI on Tool |
|
|
Control Signals - 24 VDC Pass-through Signals - 5 Amp/250V Remote I/O pass-through signals - 4 Amp/250V |
|
VF2
|
|
Discrete, 26-pin Amphenol, 19-pin Block. Supports L/U/R1/R2 Sensors and Integrated Valve. VF2-M Supports TSI on the Tool Side |
|
|
Control Signals - 12 @ 5 Amp/250V, 5 Amp / 24VDC |
|
VJ4
|
|
Interbus Power Pass-through and I/O Connection Module with Arc Prevention |
|
|
Input Power - 5 Amp/12-30VDC Output Power - 5 Amp/21-26VDC |
|
VK2
|
|
IO-Link Module with (4) M12 5-Pin Connectors for I/O Link Pass-Thru, (3) M12 5-Pin Connectors for Valve Control and Locked, Unlocked, and Ready-to-Lock Sensor Inputs. Supports Integrated Valve Control. |
|
|
Control Signals - 24VDC Pass-through Signals - 3 Amp/24V |
|
|
|
离散的通讯模块
RP5
|
|
Discrete PROFIBUS Pass-Through Module with B-coded M12 Connector |
|
|
|
先前产品版本: |
AQ3-T
|
,
|
B15
|
,
|
DD3
|
,
|
DKD
|
,
|
DU2
|
,
|
EC6
|
,
|
FF3
|
,
|
FH6
|
,
|
GB8 Family
|
,
|
PA5
|
,
|
RF5
|
,
|
RM19
|
,
|
SM19
| |
|
Custom Application Tool Changer Models and Modules
|
|