Standard Calibrations (US)
Calibration | Fx,Fy | Fz | Tx,Ty | Tz | Fx,Fy | Fz | Tx,Ty | Tz |
US-105-185 | 105 lbf | 210 lbf | 185 lbf-in | 185 lbf-in | 1/52 lbf | 7/260 lbf | 5/168 lbf-in | 1/48 lbf-in |
US-210-370 | 210 lbf | 420 lbf | 370 lbf-in | 370 lbf-in | 5/128 lbf | 3/64 lbf | 5/84 lbf-in | 1/24 lbf-in |
US-420-740 | 420 lbf | 840 lbf | 740 lbf-in | 740 lbf-in | 5/64 lbf | 3/32 lbf | 5/42 lbf-in | 1/12 lbf-in |
| SENSING RANGES | RESOLUTION |
View Standard (US) Complex Loading Graph
Metric Calibrations (SI)
Calibration | Fx,Fy | Fz | Tx,Ty | Tz | Fx,Fy | Fz | Tx,Ty | Tz |
SI-475-20 | 475 N | 950 N | 20 Nm | 20 Nm | 9/112 N | 3/28 N | 5/1496 Nm | 7/2992 Nm |
SI-950-40 | 950 N | 1900 N | 40 Nm | 40 Nm | 9/56 N | 3/14 N | 5/748 Nm | 7/1496 Nm |
SI-1900-80 | 1900 N | 3800 N | 80 Nm | 80 Nm | 9/28 N | 3/7 N | 5/374 Nm | 7/748 Nm |
| SENSING RANGES | RESOLUTION |
View Metric (SI) Complex Loading Graph
*The resolution is typical for most applications and can be improved with filtering.
**Resolutions quoted are the effective resolution after dropping four counts of noise.
***Applied loads must be within range in each of the six axes for the F/T sensor to measure correctly.
ATI's F/T calibrations are traceable to the National Institute of Standards and Technology (NIST). ATI certifies sensors are calibrated in accordance with applicable ATI procedures. These procedures are compliant with the ISO 9001 standard to ensure that products are within ATI specifications.
Contact your sales representative for accuracy information.
|
Single-Axis Overload
|
Fxy
|
±13000 N
|
Fz
|
±27000 N
|
Txy
|
±500 Nm
|
Tz
|
±610 Nm
|
Stiffness (Calculated)
|
X-axis & Y-axis forces (Kx, Ky)
|
7,7x107 N/m
|
Z-axis force (Kz)
|
1,2x108 N/m
|
X-axis & Y-axis torque (Ktx, Kty)
|
8,1x104 Nm/rad
|
Z-axis torque (Ktz)
|
1,3x105 Nm/rad
|
Resonant Frequency
|
Fx, Fy, Tz
|
2400 Hz
|
Fz, Tx, Ty
|
3100 Hz
|
Physical Specifications
|
Weight*
|
0,635 kg
|
Diameter*
|
85,1 mm
|
Height*
|
29,8 mm
|
* Specifications include standard interface plates.
|
9230-05-1323.pdf |
Mini85 Transducer with 20mm Through-Hole
|
9230-05-1394.pdf |
Mini85 Transducer
|
|
Manuais F/T
|
|
Net F/T
|
|
Manual Net F/T
|
Para clientes que desejam acessar os dados F/T pela rede. É necessário poder utilizar software ATI ou escrever seu próprio software de rede. (Entre em contato com a ATI para receber o manual das versões firmware anteriores a 2.0.00)
|
|
|
|
|
|
|
Manual OEM do Net F/T
|
Para clientes que constroem seu próprio Net F/T Box ou integram os componentes do Net Box em um alojamento existente.
|
|
|
|
|
|
|
NETB Drawing
|
Drawing of the Net Box, used with 9105-NET-x sensors with internal digitization electronics. Most NET F/T Gamma/Delta/Omega/Theta model sensors will use this box.
|
|
|
|
|
NETBA Drawing
|
Drawing of the Net Box with analog board, used with NET F/T Nano/Mini sensors or other sensors without internal electronics.
|
|
|
|
|
NETB-PN2 Drawing
|
Drawing of the Net Box with Profinet and AIDA push-pull connectors.
|
|
|
|
|
Wireless F/T
|
|
|
|
EtherCAT F/T
|
|
|
EtherCAT Manual
|
For customers who want information for initial setup and installation for the EtherCAT F/T System (For ECAT Axia sensors use the ECAT Axia F/T Manual below).
|
|
|
|
|
|
|
|
Digital F/T
|
|
|
Digital F/T Manual
|
For customers who access F/T data over a high-speed RS-485 bus (For RS485 Axia sensors use the Serial Axia F/T manual below).
|
|
|
|
|
|
DAQ F/T
|
|
|
Manual DAQ F/T
|
Para clientes realizando a interface com a placa DAQ do computador. É necessário poder rodar software ATI.
|
|
|
|
|
|
|
|
|
PS-1 DAQ Power Supply Drawing
|
Drawing of the power supply box used with 9105-TIF-x sensors with internal amplification electronics. Most DAQ F/T Gamma/Delta/Omega/Theta model sensors will use this box.
|
|
|
|
|
|
|
|
|
|
Controlador F/T
|
|
|
|
TWE F/T
|
|
|
Manual F/T TWE
|
Para clientes que projetarão seu próprio condicionamento de sinal e amplificação. Deve ser considerado somente para transdutores Nano e Mini.
|
|
|
|
|
|
Axia F/T
|
|
|
9230-05-1543
|
Axia80 Force/Torque Sensor Product Family – Drawing
|
|
|
|
|
|
|
ECAT Axia80 F/T Manual
|
For Axia80 customers who wish to access F/T data on robots with EtherCAT communications.
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
ECAT Axia90 F/T Manual
|
For Axia90 customers who wish to access F/T data on robots with EtherCAT communications.
|
|
|
|
|
|
|
|
|
|
|
9630-05-0006
|
Axia130 Force/Torque Sensor Product Family – Drawing
|
|
|
|
|
|
|
|
|
|
|
|
Robot Specific F/T |
|
|
9105-UR-Axia80 Kit Drawing
|
This drawing is not currently available. Please see either CB or E manual below or contact F/T Applications Support for details.
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Seção de Transdutores
|
|
|
Manual da Seção do Transdutor
|
Para uso com todos os manuais acima. Contém Especificações, Propriedades Físicas, Diagramas, etc. de todos os modelos de Transdutores.
|
|
|
|
|
|
|
Software Documentation
|
|
|
F/T Data Viewer Manual
|
For customers using the F/T Data Viewer PC program to view and log data from NET F/T, Ethernet Axia, and RS485 Axia sensors.
|
|
|
|
|
|
|
Adendos
|
|
|
|
|
9105-TW-MINI85-E |
Mini85 Transducer with Radial Exit Cable and Integrated Strain Relief
|
9105-TW-MINI85TH20-E |
Mini85 F/T transducer with 20mm thru-hole and strain relieved radial-exit cable
|
|