Standard Calibrations (US)
Calibration | Fx,Fy | Fz | Tx,Ty | Tz | Fx,Fy | Fz | Tx,Ty | Tz |
US-3-1 | 3 lbf | 4.25 lbf | 1 lbf-in | 1 lbf-in | 1/1280 lbf | 1/1280 lbf | 1/8000 lbf-in | 1/8000 lbf-in |
US-6-2 | 6 lbf | 8.5 lbf | 2 lbf-in | 2 lbf-in | 1/640 lbf | 1/640 lbf | 1/4000 lbf-in | 1/4000 lbf-in |
US-12-4 | 12 lbf | 17 lbf | 4 lbf-in | 4 lbf-in | 1/320 lbf | 1/320 lbf | 1/2000 lbf-in | 1/2000 lbf-in |
| SENSING RANGES | RESOLUTION |
View Standard (US) Complex Loading Graph
Metric Calibrations (SI)
Calibration | Fx,Fy | Fz | Tx,Ty | Tz | Fx,Fy | Fz | Tx,Ty | Tz |
SI-12-0.12 | 12 N | 17 N | 120 Nmm | 120 Nmm | 1/320 N | 1/320 N | 1/64 Nmm | 1/64 Nmm |
SI-25-0.25 | 25 N | 35 N | 250 Nmm | 250 Nmm | 1/160 N | 1/160 N | 1/32 Nmm | 1/32 Nmm |
SI-50-0.5 | 50 N | 70 N | 500 Nmm | 500 Nmm | 1/80 N | 1/80 N | 1/16 Nmm | 1/16 Nmm |
| SENSING RANGES | RESOLUTION |
View Metric (SI) Complex Loading Graph
*The resolution is typical for most applications and can be improved with filtering.
**Resolutions quoted are the effective resolution after dropping four counts of noise.
***Applied loads must be within range in each of the six axes for the F/T sensor to measure correctly.
ATI's F/T calibrations are traceable to the National Institute of Standards and Technology (NIST). ATI certifies sensors are calibrated in accordance with applicable ATI procedures. These procedures are compliant with the ISO 9001 standard to ensure that products are within ATI specifications.