Standard Calibrations (US)
Calibration | Fx,Fy | Fz | Tx,Ty | Tz | Fx,Fy | Fz | Tx,Ty | Tz |
US-150-250 | 150 lbf | 375 lbf | 250 lbf-in | 250 lbf-in | 5/112 lbf | 1/16 lbf | 1/20 lbf-in | 7/240 lbf-in |
US-300-500 | 300 lbf | 750 lbf | 500 lbf-in | 500 lbf-in | 5/56 lbf | 1/8 lbf | 1/10 lbf-in | 7/120 lbf-in |
US-600-1000 | 600 lbf | 1500 lbf | 1000 lbf-in | 1000 lbf-in | 5/28 lbf | 1/4 lbf | 1/5 lbf-in | 7/60 lbf-in |
| SENSING RANGES | RESOLUTION |
View Standard (US) Complex Loading Graph
Metric Calibrations (SI)
Calibration | Fx,Fy | Fz | Tx,Ty | Tz | Fx,Fy | Fz | Tx,Ty | Tz |
SI-700-30 | 700 N | 1700 N | 30 Nm | 30 Nm | 1/6 N | 7/24 N | 9/1600 Nm | 1/320 Nm |
SI-1400-60 | 1400 N | 3400 N | 60 Nm | 60 Nm | 1/3 N | 7/12 N | 9/800 Nm | 1/160 Nm |
SI-2800-120 | 2800 N | 6800 N | 120 Nm | 120 Nm | 3/4 N | 1 1/4 N | 9/400 Nm | 1/80 Nm |
| SENSING RANGES | RESOLUTION |
View Metric (SI) Complex Loading Graph
*The resolution is typical for most applications and can be improved with filtering.
**Resolutions quoted are the effective resolution after dropping four counts of noise.
***Applied loads must be within range in each of the six axes for the F/T sensor to measure correctly.
ATI's F/T calibrations are traceable to the National Institute of Standards and Technology (NIST). ATI certifies sensors are calibrated in accordance with applicable ATI procedures. These procedures are compliant with the ISO 9001 standard to ensure that products are within ATI specifications.
Contact your sales representative for accuracy information.
|