$ EZ-EDS Version 3.9 Generated Electronic Data Sheet [File] DescText = "DU3 Master Module EDS File"; CreateDate = 04-13-2016; CreateTime = 17:34:37; ModDate = 04-13-2016; ModTime = 17:34:44; Revision = 1.1; HomeURL = "http://www.ati-ia.com"; [Device] VendCode = 555; VendName = "ATI Industrial Automation"; ProdType = 7; ProdTypeStr = "General Purpose Discrete I/O"; ProdCode = 205; MajRev = 1; MinRev = 1; ProdName = "DU Master Module"; Icon = "ATI1.ICO"; DNetQC = 0x0001, 500; [IO_Info] Default = 0x0001; PollInfo = 0x000D, 1, 1; COSInfo = 0x0005, 1, 1; CyclicInfo = 0x0009, 1, 1; Input1 = 2, 16, 0x000D, "Status", 6, "20 04 24 07 30 03", ""; Output1 = 1, 5, 0x000D, "Status", 6, "20 04 24 25 30 03", ""; [ParamClass] MaxInst = 0; Descriptor = 0x000B; CfgAssembly = 0; [Params] Param1 = 0, $ reserved, shall equal 0 6,"20 08 24 01 30 03", $ Link Path Size, Link Path 0x0032, $ Descriptor 0xC1, $ Data Type 1, $ Data Size in bytes "Locked", $ name "", $ units "Locked Proximity Sensor", $ help string 0,1,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Enum1 = 0,"Not Locked", 1,"Locked"; Param2 = 0, $ reserved, shall equal 0 6,"20 08 24 02 30 03", $ Link Path Size, Link Path 0x0032, $ Descriptor 0xC1, $ Data Type 1, $ Data Size in bytes "Unlocked", $ name "", $ units "Unlocked Proximity Sensor", $ help string 0,1,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Enum2 = 0,"Not Unlocked", 1,"Unlocked"; Param3 = 0, $ reserved, shall equal 0 6,"20 08 24 03 30 03", $ Link Path Size, Link Path 0x0032, $ Descriptor 0xC1, $ Data Type 1, $ Data Size in bytes "Input and Logic Power Good", $ name "", $ units "Monitors DeviceNet Voltage range", $ help string 0,1,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Enum3 = 0,"Not Good", 1,"Good"; Param4 = 0, $ reserved, shall equal 0 6,"20 08 24 04 30 03", $ Link Path Size, Link Path 0x0032, $ Descriptor 0xC1, $ Data Type 1, $ Data Size in bytes "Valve Power Available",$ name "", $ units "Monitors Valve Power range", $ help string 0,1,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Enum4 = 0,"Aux Power Off", 1,"Aux Power On"; Param5 = 0, $ reserved, shall equal 0 6,"20 08 24 05 30 03", $ Link Path Size, Link Path 0x0032, $ Descriptor 0xC1, $ Data Type 1, $ Data Size in bytes "RTL", $ name "", $ units "Ready-to-Lock Proximity Sensors in series", $ help string 0,1,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Enum5 = 0,"Off", 1,"On"; Param6 = 0, $ reserved, shall equal 0 6,"20 08 24 06 30 03", $ Link Path Size, Link Path 0x0032, $ Descriptor 0xC1, $ Data Type 1, $ Data Size in bytes "Thermal 1", $ name "", $ units "Thermal 1 sensor", $ help string 0,1,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Enum6 = 0,"Off", 1,"On"; Param7 = 0, $ reserved, shall equal 0 6,"20 08 24 07 30 03", $ Link Path Size, Link Path 0x0032, $ Descriptor 0xC1, $ Data Type 1, $ Data Size in bytes "No TSI or TSRV Discrepancy Present", $ name "", $ units "No TSIx/TSRVx or TSRVs or TSIs mismatching", $ help string 0,1,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Enum7 = 0,"Off", 1,"On"; Param8 = 0, $ reserved, shall equal 0 6,"20 08 24 08 30 03", $ Link Path Size, Link Path 0x0032, $ Descriptor 0xC1, $ Data Type 1, $ Data Size in bytes "Air Supply Pressure Available", $ name "", $ units "True if air supply greater than 60 psi", $ help string 0,1,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Enum8 = 0,"Off", 1,"On"; Param9 = 0, $ reserved, shall equal 0 6,"20 08 24 09 30 03", $ Link Path Size, Link Path 0x0032, $ Descriptor 0xC1, $ Data Type 1, $ Data Size in bytes "Tool-ID 1", $ name "", $ units "Tool-ID bit 1", $ help string 0,1,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Enum9 = 0,"Off", 1,"On"; Param10 = 0, $ reserved, shall equal 0 6,"20 08 24 0a 30 03", $ Link Path Size, Link Path 0x0032, $ Descriptor 0xC1, $ Data Type 1, $ Data Size in bytes "Tool-ID 2", $ name "", $ units "Tool-ID bit 2", $ help string 0,1,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Enum10 = 0,"Off", 1,"On"; Param11 = 0, $ reserved, shall equal 0 6,"20 08 24 0b 30 03", $ Link Path Size, Link Path 0x0032, $ Descriptor 0xC1, $ Data Type 1, $ Data Size in bytes "Tool-ID 4", $ name "", $ units "Tool-ID bit 3", $ help string 0,1,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Enum11 = 0,"Off", 1,"On"; Param12 = 0, $ reserved, shall equal 0 6,"20 08 24 0c 30 03", $ Link Path Size, Link Path 0x0032, $ Descriptor 0xC1, $ Data Type 1, $ Data Size in bytes "Tool-ID 8", $ name "", $ units "Tool-ID bit 4", $ help string 0,1,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Enum12 = 0,"Off", 1,"On"; Param13 = 0, $ reserved, shall equal 0 6,"20 08 24 0d 30 03", $ Link Path Size, Link Path 0x0032, $ Descriptor 0xC1, $ Data Type 1, $ Data Size in bytes "Tool In Stand", $ name "", $ units "True if TSI1/2 are high, pulsing, and no mismatches", $ help string 0,1,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Enum13 = 0,"Off", 1,"On"; Param14 = 0, $ reserved, shall equal 0 6,"20 08 24 0e 30 03", $ Link Path Size, Link Path 0x0032, $ Descriptor 0xC1, $ Data Type 1, $ Data Size in bytes "Unlatch Enabled", $ name "", $ units "True if conditions allow for an unlatch", $ help string 0,1,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Enum14 = 0,"Off", 1,"On"; Param15 = 0, $ reserved, shall equal 0 6,"20 08 24 0f 30 03", $ Link Path Size, Link Path 0x0032, $ Descriptor 0xC1, $ Data Type 1, $ Data Size in bytes "TSI1/TSI2 Relays Energized", $ name "", $ units "Unlatch output connected to valve", $ help string 0,1,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Enum15 = 0,"Off", 1,"On"; Param16 = 0, $ reserved, shall equal 0 6,"20 08 24 10 30 03", $ Link Path Size, Link Path 0x0032, $ Descriptor 0xC1, $ Data Type 1, $ Data Size in bytes "Tool Power ON", $ name "", $ units "Arc prevention circuit on and power provided to tool", $ help string 0,1,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Enum16 = 0,"Off", 1,"On"; Param17 = 0, $ reserved, shall equal 0 6,"20 09 24 01 30 03", $ Link Path Size, Link Path 0x0022, $ Descriptor 0xC1, $ Data Type 1, $ Data Size in bytes "Unlatch", $ name "", $ units "Turn on Unlatch Solenoid", $ help string 0,1,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Enum17 = 0,"Off", 1,"On"; Param18 = 0, $ reserved, shall equal 0 6,"20 09 24 02 30 03", $ Link Path Size, Link Path 0x0022, $ Descriptor 0xC1, $ Data Type 1, $ Data Size in bytes "Latch", $ name "", $ units "Turn on Latch Solenoid", $ help string 0,1,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Enum18 = 0,"Off", 1,"On"; Param19 = 0, $ reserved, shall equal 0 6,"20 09 24 04 30 03", $ Link Path Size, Link Path 0x0022, $ Descriptor 0xC1, $ Data Type 1, $ Data Size in bytes "Clear Errors", $ name "", $ units "Clear Errors to Resume Normal Operation", $ help string 0,1,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Enum19 = 0,"Off", 1,"On"; Param20 = 0, $ reserved, shall equal 0 6,"20 09 24 05 30 03", $ Link Path Size, Link Path 0x0022, $ Descriptor 0xC1, $ Data Type 1, $ Data Size in bytes "Soft Start Enable", $ name "", $ units "Enables soft starting arc prevention", $ help string 0,1,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Enum20 = 0,"Off", 1,"On"; Param21 = 0, $ reserved, shall equal 0 6,"20 03 24 01 30 0A", $ Link Path Size, Link Path 0x0003, $ Descriptor 0xC1, $ Data Type 1, $ Data Size in bytes "Quick Connect Mode", $ name "", $ units "0=disabled, 1=enabled",$ help string 0,1,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Enum21 = 0,"Off", 1,"On";