$ EZ-EDS Version 1.0 Generated Electronic Data Sheet [File] DescText = "DeviceNet Network"; CreateDate = 12-13-2005; CreateTime = 15:41:26; ModDate = 12-13-2005; ModTime = 15:41:29; Revision = 5.01; $ vendor code was 59 [Device] VendCode = 555; VendName = "ATI"; ProdType = 7; ProdTypeStr = "General Purpose Discrete I/O"; ProdCode = 560; MajRev = 5; MinRev = 1; ProdName = "DA Tool"; Catalog = "Catalog Name Here"; DNetQC = 0x0002, 150; [IO_Info] Default = 0x0001; PollInfo = 0x0001, 1, 0; Input1 = 2, 0, 0x0001, "Producing IO/Data", 6, "20 04 24 64 30 03", "Help"; [ParamClass] MaxInst = 8; Descriptor = 0x0009; CfgAssembly = 0; [Params] Param1 = 0, $ parameter value slot 6,"20 64 24 01 30 01", $ link size and path 0x003C, $ descriptor 8, 1, $ data type, 1 byte(s) "Switch 1 Instance 1", $ parameter name "", $ units string "Switch 1\n" "\n" "If value is greater than 9 then switch is malfuctioning", 0,15,0, 1,1,1,0, 0,0,0,0, 0; Param2 = 0, $ parameter value slot 6,"20 64 24 01 30 02", $ link size and path 0x003C, $ descriptor 8, 1, $ data type, 1 byte(s) "Switch 2 Instance 1", $ parameter name "", $ units string "Switch 2\n" "\n" "If value is greater than 9 then switch is malfuctioning", 0,15,0, 1,1,1,0, 0,0,0,0, 0; Param3 = 0, $ parameter value slot 6,"20 64 24 01 30 03", $ link size and path 0x003C, $ descriptor 8, 1, $ data type, 1 byte(s) "Switch 3 Instance 1", $ parameter name "", $ units string "Switch 3\n" "\n" "If value is greater than 9 then switch is malfuctioning", 0,15,0, 1,1,1,0, 0,0,0,0, 0; Param4 = 0, $ parameter value slot 6,"20 64 24 01 30 04", $ link size and path 0x003C, $ descriptor 8, 1, $ data type, 1 byte(s) "Switch 4 Instance 1", $ parameter name "", $ units string "Switch 4\n" "\n" "If value is greater than 9 then switch is malfuctioning", 0,15,0, 1,1,1,0, 0,0,0,0, 0; Param5 = 0, $ parameter value slot 6,"20 64 24 01 30 05", $ link size and path 0x003C, $ descriptor 8, 1, $ data type, 1 byte(s) "Switch 5 Instance 1", $ parameter name "", $ units string "Switch 5\n" "\n" "If value is greater than 9 then switch is malfuctioning", 0,15,0, 1,1,1,0, 0,0,0,0, 0; Param6 = 0, $ parameter value slot 6,"20 64 24 01 30 06", $ link size and path 0x003C, $ descriptor 8, 1, $ data type, 1 byte(s) "Tool ID Instance 1", $ parameter name "", $ units string "Tool ID\n" "\n" "Error is indicated by a value of 255 (0xff)", 0,255,0, 1,1,1,0, 0,0,0,0, 0; Param7 = 0, $ parameter value slot 6,"20 64 24 01 30 07", $ link size and path 0x003C, $ descriptor 8, 1, $ data type, 1 byte(s) "Tool ID Instance 1", $ parameter name "", $ units string "Tool ID\n" "\n" "Two nibbles in one byte (SW4=low) (SW5=high)", 0,255,0, 1,1,1,0, 0,0,0,0, 0; Param8 = 0, $ parameter value slot 6,"20 64 24 01 30 08", $ link size and path 0x003E, $ descriptor 4, 1, $ data type, 1 byte(s) "Tool ID Flag Instance 1", $ parameter name "", $ units string "Tool ID Flag\n" "\n" "Indicates if Tool ID range is above 255 decimal", 0,1,0, 1,1,1,0, 0,0,0,0, 0; Param9 = 0, $ reserved, shall equal 0 6,"20 03 24 01 30 0A", $ Link Path Size, Link Path 0x0003, $ Descriptor 4, $ Data Type 1, $ Data Size in bytes "Quick Connect Mode", $ name "", $ units "0=disabled\n" "1=enabled", $ help string 0,1,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places [EnumPar] Param8 = "OK", "OVERFLOW"; Param9 = "Disabled", "Enabled"; [Groups]